Stay connected

Trending News

Siemens Solid Edge File Parsing
ICS, News, Vulnerabilities

Siemens Solid Edge File Parsing 

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Solid Edge Vulnerabilities: Out-of-bounds Write, Improper Restriction of XML External Entity Reference, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead to a crash, arbitrary code execution, or data extraction on the target…

Siemens Web Server of SCALANCE X200
ICS, News, Vulnerabilities

Siemens Web Server of SCALANCE X200 

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Web Server of SCALANCE X200 Vulnerabilities: Heap-based Buffer Overflow, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a buffer overflow condition resulting in remote code execution. 3. TECHNICAL DETAILS…

Siemens SINEMA Remote Connect Server
ICS, News, Vulnerabilities

Siemens SINEMA Remote Connect Server 

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEMA Remote Connect Server Vulnerabilities: Missing Release of Resource after Effective Lifetime, Infinite Loop 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a memory leak or an infinite loop…

Siemens LOGO! Soft Comfort
ICS, News, Vulnerabilities

Siemens LOGO! Soft Comfort 

1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Nucleus Vulnerability: Use of Insufficiently Random Values 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow a local attacker to take over the system where the software is installed. 3. TECHNICAL DETAILS 3.1 AFFECTED…

Siemens and PKE Control Center Server
ICS, News, Vulnerabilities

Siemens and PKE Control Center Server 

1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low attack complexity Vendors: Siemens/PKE Equipment: Control Center Server (CCS) Vulnerabilities: Cleartext Storage of Sensitive Information in GUI, Improper Authentication, Relative Path Traversal, Use of a Broken or Risky Cryptographic Algorithm, Exposed Dangerous Method or Function, Path Traversal, Cleartext Storage in…

Siemens TIM 4R-IE Devices
ICS, News, Vulnerabilities

Siemens TIM 4R-IE Devices 

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: TIM 4R-IE Vulnerabilities: Incorrect Type Conversion or Cast, Improper Input Validation, Improper Authentication, Security Features, Null Pointer Dereference, Data Processing Errors, Exposure of Sensitive Information to an Unauthorized Actor, Race Condition 2. RISK EVALUATION Successful…

Siemens SIMOTICS CONNECT 400
ICS, News, Vulnerabilities

Siemens SIMOTICS CONNECT 400 

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMOTICS CONNECT 400 Vulnerabilities: Improper Null Termination, Out-of-bounds Read, Access of Memory Location After End of Buffer, Use of Insufficiently Random Values 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to…

Siemens Nucleus DNS
ICS, News, Vulnerabilities

Siemens Nucleus DNS 

1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Nucleus Vulnerability: Use of Insufficiently Random Values 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to poison the DNS cache or spoof DNS resolving. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The…

Medtronic Conexus Radio Frequency Telemetry Protocol
ICS, News, Vulnerabilities

Medtronic Conexus Radio Frequency Telemetry Protocol (Update C) 

1. EXECUTIVE SUMMARY CVSS v3 9.3 ATTENTION: Exploitable with adjacent access/low attack complexity Vendor: Medtronic Equipment: MyCareLink Monitor, CareLink Monitor, CareLink 2090 Programmer, specific Medtronic implanted cardiac devices listed below Vulnerabilities: Improper Access Control, Cleartext Transmission of Sensitive Information 2. UPDATE INFORMATION This updated advisory is a follow-up to…