(I)IoT Security News
ICS, News, Vulnerabilities

Bosch Rexroth IndraDrive

Bosch Rexroth IndraDrive

Bosch Rexroth IndraDrive

1. EXECUTIVE SUMMARY

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service, rendering the device unresponsive by sending arbitrary UDP messages.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Bosch Rexroth reports that the following versions of IndraDrive, servo drive system, are affected:

3.2 Vulnerability Overview

3.2.1 Uncontrolled Resource Consumption CWE-400

A vulnerability in the PROFINET stack implementation of the IndraDrive of Bosch Rexroth allows an attacker to cause a denial-of-service, rendering the device unresponsive by sending arbitrary UDP messages.

CVE-2024-48989 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2024-48989. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

3.4 RESEARCHER

Roni Gavrilov from OTORIO reported this vulnerability to CISA.

4. MITIGATIONS

Bosch Rexroth has fixed this vulnerability starting with FWA-INDRV-MP-20V36. Bosch Rexroth recommends updating as soon as possible.

In use cases in which a device update is not possible or not feasible, Bosch Rexroth recommends compensatory measures which prevent or at least complicate taking advantage of the vulnerability. Always define such compensatory measures individually, in the context of the operational environment.

Some possible measures are described in “Security Manual Electric Drives and Controls”, like network segmentation. In general, it is highly recommended to implement the measures described in “Security Manual Drives and Controls”.

For more information, refer to the Bosch PSIRT Security Advisory BOSCH-SA-2584444

Please contact the Bosch PSIRT if you have feedback, comments, or additional information about this vulnerability at: psirt@bosch.com .

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

Source:

https://www.cisa.gov/news-events/ics-advisories/icsa-24-312-03