(I)IoT Security News
News, Vulnerabilities

Gemalto Sentinel UltraPro

1. EXECUTIVE SUMMARY

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow execution of unauthorized code or commands.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Sentinel UltraPro encryption keys are affected:

3.2 VULNERABILITY OVERVIEW

3.2.1    UNCONTROLLED SEARCH PATH ELEMENT CWE-427

The uncontrolled search path element vulnerability enables an attacker to load and execute a malicious file from the ux32w.dll in Sentinel UltraPro.

CVE-2019-6534 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

3.4 RESEARCHER

ADLab of Venustech reported this vulnerability to NCCIC.

4. MITIGATIONS

Users who have Sentinel UltraPro Client Library ux32w.versions v1.3.0, v1.3.1 or v1.3.2 are advised to upgrade to Sentinel UtraPro v1.3.3 in order to enable this security update. The security update is found at the following link:

https://supportportal.gemalto.com/csm?id=kb_article_view&sysparm_article=KB0017694

For additional information, please see Gemalto’s security bulletin at:

https://sentinel.gemalto.com/technical-support/security-updates-sm/

NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:

NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.

No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.

 

Source:

https://ics-cert.us-cert.gov/advisories/ICSA-19-073-02

 

Related posts

Global Brain and KDDI invest in IoT device management platform Resin

IoT
6 years ago

Siemens Industrial Products with OPC UA (Update F)

(I) IoT
4 years ago

Siemens Industrial Products Local Privilege Escalation Vulnerability (Update I) Original release date: October 10, 2019

(I) IoT
5 years ago
Exit mobile version