(I)IoT Security News
ICS, News, Vulnerabilities

Siemens Solid Edge

Siemens Solid Edge

1. EXECUTIVE SUMMARY

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow arbitrary code execution on an affected system.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Solid Edge, a portfolio of software tools, are affected:

3.2 VULNERABILITY OVERVIEW

3.2.1    OUT-OF-BOUNDS WRITE CWE-787

The affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2020-28381 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.2    OUT-OF-BOUNDS WRITE CWE-787

The affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2020-28382 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.3    OUT-OF-BOUNDS WRITE CWE-787

The affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out-of-bounds write past the memory location of a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2020-28383 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.4    STACK-BASED BUFFER OVERFLOW CWE-121

The affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2020-28384 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.5    OUT-OF-BOUNDS WRITE CWE-787

The affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2020-28386 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.6    STACK-BASED BUFFER OVERFLOW CWE-121

The affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2020-26989 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

3.4 RESEARCHER

rgod, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has published a security advisory and released an update to Version SE2021MP2 or later for Solid Edge and recommends users update to the latest version (login required).

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

As a general security measure, Siemens strongly recommends users protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to Siemens’ operational guidelines for Industrial Security, and follow the recommendations in the product manual.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.

Source:

https://iotsecuritynews.com/

Related posts

Multiple Embedded TCP/IP Stacks (Update A)

(I) IoT
4 years ago

Siemens SCALANCE X Switches (Update A)

(I) IoT
4 years ago

Apache Tomcat Patches Important Security Vulnerabilities

(I) IoT
6 years ago
Exit mobile version