Rockwell Automation MicroLogix 1400 (Update A)

Rockwell Automation MicroLogix 1400

1. EXECUTIVE SUMMARY

2. UPDATE INFORMATION

This updated advisory is a follow-up to the original advisory titled ICSA-21-033-01 Rockwell Automation MicroLogix 1400 that was published February 2, 2021, to the ICS webpage on us-cert.cisa.gov.

3. RISK EVALUATION

Successful exploitation of this vulnerability may result in a denial-of-service condition.

4. TECHNICAL DETAILS

4.1 AFFECTED PRODUCTS

Rockwell Automation reports the vulnerability affects the following MicroLogix 1400 controllers:

4.2 VULNERABILITY OVERVIEW

4.2.1    CLASSIC BUFFER OVERFLOW CWE-120

A remote unauthenticated attacker may be able to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a denial-of-service condition. The FAULT LED will flash RED and communications may be lost. Recovery from denial-of-service condition requires the fault to be cleared by the user.

CVE-2021-22659 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:H).

4.3 BACKGROUND

4.4 RESEARCHER

——— Begin Update A Part 1 of 2 ———

Parul Sindhwad and Dr. Faruk Kazi of COE-CNDS, Veermata Jijabai Technological Institute (VJTI), India reported this vulnerability to Rockwell Automation.

——— End Update A Part 1 of 2 ———

5. MITIGATIONS

Rockwell Automation recommends users with the affected controller to mitigate risk. They encourage, when possible, to combine this guidance with the general security guidelines for a comprehensive defense-in-depth strategy. Please subscribe to updates to this advisory and the Industrial Security Advisory Index to stay notified.

All users, if applicable, may disable Modbus TCP support if it is not necessary for their MicroLogix 1400 implementation. Without Modbus TCP enabled, a potential attacker does not have access to exploit the device using this vulnerability.

——— Begin Update A Part 2 of 2 ———

For additional information see Rockwell Automation Security Advisory PN1545.

——— End Update A Part 2 of 2 ———

Rockwell Automation recommends the following network-based vulnerability mitigations for embedded products:

Rockwell Automation recommends the following software/PC-based mitigation strategies:

Rockwell Automation recommends the following general mitigations:

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target this vulnerability. High skill level is needed to exploit.

Source:

https://us-cert.cisa.gov/ics/advisories/icsa-21-033-01