Siemens LOGO! 8 BM Devices 

1. EXECUTIVE SUMMARY

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to execute code remotely, put the device into a denial-of-service state, or retrieve parts of the memory.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports these vulnerabilities affect the following LOGO! 8 BM (Base Module) devices: 

3.2 VULNERABILITY OVERVIEW

3.2.1    CLASSIC BUFFER OVERFLOW CWE-120

Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, obtain control over the instruction counter, and run custom code.

CVE-2022-36361 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.2    IMPROPER INPUT VALIDATION CWE-20

Affected devices do not conduct certain validations during interaction. This could allow an unauthenticated remote attacker to manipulate the device’s IP address, making the device unreachable until the device could be power cycled.

CVE-2022-36362 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.3    IMPROPER VALIDATION OF SPECIFIED INDEX, POSITION, OR OFFSET IN INPUT CWE-1285

Affected devices do not properly validate an offset value, which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of memory content.

CVE-2022-36363 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).

3.3 BACKGROUND

3.4 RESEARCHER

Cyber Research Group from Raytheon UK reported these vulnerabilities to Siemens.

4. MITIGATIONS

Siemens is preparing updates and recommends specific countermeasures for products where updates are not yet available:

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following the recommendations in the product manuals.

Siemens has provided additional information on industrial security

For more information, see the associated Siemens Security Advisory SSA-955858 in HTML or CSAF formats.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Source:

Related posts

ABB eSOMS

(I) IoT
5 years ago

Intel Data Center Manager SDK

(I) IoT
6 years ago

Phoenix Contact Automation Worx Software Suite

(I) IoT
4 years ago
Exit mobile version