Siemens Embedded TCP/IP Stack Vulnerabilities–AMNESIA:33 (Update B)
1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: ENTRON 3VA COM100/800, SENTRON 3VA DSP800, SENTRON PAC2200, SENTRON PAC3200T, SENTRON PAC3200, SENTRON PAC4200, SIRIUS 3RW5 Vulnerability: Integer Overflow 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled…
Siemens Industrial Products SNMP Vulnerabilities (Update C)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: Various SCALANCE, SIMATIC, SIPLUS products Vulnerabilities: Data Processing Errors, NULL Pointer Dereference 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-20-042-02 Siemens Industrial Products SNMP Vulnerabilities (Update…
Siemens Industrial Real-Time (IRT) Devices (Update E)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: Industrial Real-Time (IRT) Devices Vulnerability: Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-19-283-01 Siemens Industrial Real-Time (IRT) Devices (Update D) that was published…
Siemens Climatix (Update A)
1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: Climatix Vulnerability: Cross-site Scripting, Basic XSS 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-20-105-04 Siemens Climatix that was published April 14th, 2020, to the ICS webpage…
Luxion KeyShot (Update A)
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Luxion Equipment: KeyShot products Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read, Insufficient UI Warning of Dangerous Operations, Untrusted Pointer Dereference, Path Traversal 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-035-01 Luxion…
Horner Automation Cscape
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Horner Automation Equipment: Cscape Vulnerability: Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of this vulnerability may allow code execution in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of…
Siemens SIMATIC HMI Comfort Panels & SIMATIC HMI KTP Mobile Panels
1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC HMI Comfort Panels, SIMATIC HMI KTP Mobile Panels Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote attacker to gain full access to…
Rockwell Automation FactoryTalk Linx and FactoryTalk Services Platform
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Rockwell Automation Equipment: FactoryTalk Linx and FactoryTalk Services Platform Vulnerabilities: Classic Buffer overflow, Improper Check or Handling of Exceptional Conditions 2. RISK EVALUATION Successful exploitation of these vulnerabilities may result in denial-of-service conditions. 3. TECHNICAL…
Fuji Electric Tellus Lite V-Simulator and V-Server Lite
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Fuji Electric Equipment: Tellus Lite V-Simulator and V-Server Lite Vulnerabilities: Stack-based Buffer Overflow, Out-of-Bounds Read, Out-of-Bounds Write, Access of Uninitialized Pointer, Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker…
Mitsubishi Electric Multiple Products (Update A)
1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Mitsubishi Electric Equipment: Multiple Products Vulnerability: Predictable Exact Value from Previous Values 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-20-245-01 Mitsubishi Electric Multiple Products that was published September…