Medtronic Conexus Radio Frequency Telemetry Protocol
Uncategorized

Medtronic Conexus Radio Frequency Telemetry Protocol (Update B) 

1. EXECUTIVE SUMMARY CVSS v3 9.3 ATTENTION: Exploitable with adjacent access/low skill level to exploit Vendor: Medtronic Equipment: MyCareLink Monitor, CareLink Monitor, CareLink 2090 Programmer, specific Medtronic implanted cardiac devices listed below Vulnerabilities: Improper Access Control, Cleartext Transmission of Sensitive Information 2. UPDATE INFORMATION This updated advisory is a…

ABB System 800xA Base
ICS, News, Vulnerabilities

ABB System 800xA Base 

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: ABB Equipment: System 800xA Base Vulnerability: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate privileges and cause system functions to stop or malfunction. 3….

ABB Multiple System 800xA Products
ICS, News, Vulnerabilities

ABB Multiple System 800xA Products 

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: ABB Equipment: System 800xA Vulnerabilities: Incorrect Default Permissions 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to make the system node inaccessible or tamper with runtime data in the system. 3. TECHNICAL…

ABB Central Licensing System
ICS, News, Vulnerabilities

ABB Central Licensing System 

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: ABB Equipment: Central Licensing System (CLS) Vulnerabilities: Information Exposure; Improper Restriction of XML External Entity Reference; Uncontrolled Resource Consumption; Permissions, Privilege, and Access Controls; Improper Access Control 2. RISK EVALUATION Successful exploitation of these vulnerabilities…

GE Grid Solutions Reason RT Clocks
ICS, News, Vulnerabilities

GE Grid Solutions Reason RT Clocks 

1. EXECUTIVE SUMMARY CVSS v3 9.6 ATTENTION: Low skill level to exploit/exploitable remotely Vendor: GE Equipment: Grid Solutions Reason RT Clocks Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow access to sensitive information, execution of arbitrary code, and cause the device…

SWARCO CPU LS4000
ICS, News, Vulnerabilities

SWARCO CPU LS4000 

EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: SWARCO TRAFFIC SYSTEMS Equipment: CPU LS4000 Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow access to the device and disturb operations with connected devices. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS…

Inductive Automation Ignition
ICS, News, Vulnerabilities

Inductive Automation Ignition (Update A) 

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Inductive Automation Equipment: Ignition Vulnerabilities: Missing Authentication for Critical Function, Deserialization of Untrusted Data 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-20-147-01 Inductive Automation Ignition that was published…

Johnson Controls Kantech EntraPass
ICS, News, Vulnerabilities

Johnson Controls Kantech EntraPass 

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: low skill level to exploit Vendor: Kantech, a subsidiary of Johnson Controls Equipment: EntraPass Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could potentially allow an authorized low-privileged user to gain full system-level privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED…