Delta Electronics DIAScreen
ICS, News, Vulnerabilities

Delta Electronics DIAScreen 

1. EXECUTIVE SUMMARY 2. RISK EVALUATION Successful exploitation of this these vulnerabilities could crash the device being accessed; a buffer overflow condition may allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of DIAScreen, which is a component of Delta’s DIAStudio…

https://www.cisa.gov/news-events/ics-advisories/icsa-24-303-03
ICS, News, Vulnerabilities

Delta Electronics InfraSuite Device Master 

1. EXECUTIVE SUMMARY 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker to remotely execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of InfraSuite Device Master, a real-time device monitoring software, are affected: 3.2 Vulnerability Overview 3.2.1 DESERIALIZATION…

IDEC CORPORATION WindLDR and WindO/I-NV4
ICS, News, Vulnerabilities

IDEC CORPORATION WindLDR and WindO/I-NV4 

1. EXECUTIVE SUMMARY 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to obtain sensitive information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of WindLDR and WindO/I-NV4 are affected: 3.2 Vulnerability Overview 3.2.1 CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312 The affected…

AVEVA Historian Web Server
ICS, News, Vulnerabilities

AVEVA Historian Web Server 

1. EXECUTIVE SUMMARY 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an authenticated user to get read and write access to the database. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of AVEVA Historian Server, a Process database, are affected: 3.2 Vulnerability…

Siemens INTRALOG WMS
ICS, News, Vulnerabilities

Siemens INTRALOG WMS 

1. EXECUTIVE SUMMARY 2. RISK EVALUATION Successful exploitation could allow an unauthenticated attacker located in the INTRALOG WMS network to decrypt and modify client-server communication, or potentially execute arbitrary code on the application servers. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following version of Siemens…

Delta Electronics DIAScreen
ICS, News, Vulnerabilities

Delta Electronics DIAScreen 

1. EXECUTIVE SUMMARY 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a stack-based buffer overflow, resulting in execution of arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Delta Electronics DIAScreen visualization software are affected: 3.2…

Dorsett Controls InfoScan
ICS, News, Vulnerabilities

Dorsett Controls InfoScan 

1. EXECUTIVE SUMMARY 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to expose sensitive information, resulting in data theft and misuse of credentials. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Dorsett Controls products are affected: 3.2 Vulnerability Overview 3.2.1 EXPOSURE OF…