Stay connected

Trending News

Weintek EasyWeb cMT
ICS, News, Vulnerabilities

Weintek EasyWeb cMT 

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Weintek Equipment: cMT Vulnerabilities: Code Injection, Improper Access Control, Cross-site Scripting 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthenticated remote attacker to access sensitive information and execute arbitrary code to gain…

GE MU320E
ICS, News, Vulnerabilities

GE MU320E 

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GE Equipment: MU320E Vulnerabilities: Use of Hard-coded Password, Execution with Unnecessary Privileges, Inadequate Encryption Strength 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to escalate unnecessary privileges and use hard-coded credentials…

GE Reason DR60
ICS, News, Vulnerabilities

GE Reason DR60 

1. EXECUTIVE SUMMARY CVSS v3 9.8 GE Reason DR60 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GE Equipment: Reason DR60 Vulnerabilities: Hard-coded Password, Code Injection, Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to take full control of the digital…

Ovarro TBox
ICS, News, Vulnerabilities

Ovarro TBox 

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Ovarro Equipment: TBoxLT2 (All models), TBox MS-CPU32, TBox MS-CPU32-S2, TBox RM2 (All models), TBox TG2 (All models) Vulnerabilities: Code Injection, Incorrect Permission Assignment for Critical Resource, Uncontrolled Resource Consumption, Insufficiently Protected Credentials, Use of Hard-coded…

Johnson Controls Exacq Technologies exacqVision
ICS, News, Vulnerabilities

Johnson Controls Exacq Technologies exacqVision 

1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Exacq Technologies, Inc., a subsidiary of Johnson Controls Equipment: exacqVision Vulnerability: Information Exposure 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker to view system-level information about the exacqVision Web Service…

Hitachi ABB Power Grids eSOMS Telerik
ICS, News, Vulnerabilities

Hitachi ABB Power Grids eSOMS Telerik 

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Hitachi ABB Power Grids Equipment: eSOMS Telerik Vulnerabilities: Path Traversal, Deserialization of Untrusted Data, Improper Input Validation, Inadequate Encryption Strength, Insufficiently Protected Credentials, Path Traversal 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow…

Advantech WebAccess/SCADA
ICS, News, Vulnerabilities

Advantech WebAccess/SCADA 

1. EXECUTIVE SUMMARY CVSS v3 5.4 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Advantech Equipment: WebAccess/SCADA Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthorized user to steal a user’s cookie/session token or redirect an authorized user to a malicious webpage. 3….

Hitachi ABB Power Grids AFS Series
ICS, News, Vulnerabilities

Hitachi ABB Power Grids AFS Series 

1. EXECUTIVE SUMMARY Hitachi ABB Power Grids AFS Series CVSS v3 6.5 ATTENTION: Low skill level to exploit Vendor: Hitachi ABB Power Grids Equipment: AFS Series Vulnerability: Infinite Loop 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial-of-service condition on one of the ports in a…

BD Alaris 8015 PC Unit
ICS, News, Vulnerabilities

BD Alaris 8015 PC Unit (Update B) 

1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Low skill level to exploit Vendor: Becton, Dickinson and Company (BD) Equipment: BD Alaris 8015 PC Unit Vulnerabilities: Insufficiently Protected Credentials, Security Features 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSMA-17-017-02 BD Alaris 8015 Insufficiently…