Claroty Secure Remote Access Site
ICS, News, Vulnerabilities

Claroty Secure Remote Access Site 

1. EXECUTIVE SUMMARY CVSS v3 5.5 ATTENTION: Low attack complexity Vendor: Claroty Equipment: Secure Remote Access (SRA) Site Vulnerability: Authentication Bypass Using an Alternate Path or Channel 2. RISK EVALUATION Successful exploitation of this vulnerability enables an attacker with local (Linux) system access to bypass access controls for the…

FATEK WinProladder
ICS, News, Vulnerabilities

FATEK WinProladder 

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: FATEK Automation Equipment: WinProladder Vulnerabilities: Out-of-bounds Read, Out-of-bounds Write, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow for the execution of arbitrary code. 3. TECHNICAL…

CODESYS Control V2 communication
ICS, News, Vulnerabilities

CODESYS Control V2 communication 

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: CODESYS, GmbH Equipment: CODESYS V2 Runtime Toolkit, CODESYS PLCWinNT Vulnerabilities: Stack-based Buffer Overflow, Heap-based Buffer Overflow, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities may cause a heap-based buffer overflow, a stack-based buffer overflow,…

CODESYS Control V2 Linux SysFile library
ICS, News, Vulnerabilities

CODESYS Control V2 Linux SysFile library 

1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: CODESYS, GmbH Equipment: CODESYS V2 Runtime Toolkit Vulnerability: OS Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability may allow the control programmer to call additional OS functions from the PLC logic utilizing the SysFile system…

WAGO M&M Software fdtCONTAINER
ICS, News, Vulnerabilities

WAGO M&M Software fdtCONTAINER (Update C) 

1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Low skill level to exploit Vendor: M&M Software GmbH, a subsidiary of WAGO Kontakttechnik Equipment: fdtCONTAINER Vulnerability: Deserialization of Untrusted Data 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-21-021-05 WAGO M&M Software fdtCONTAINER (Update B)…

Rockwell Automation MicroLogix 1400
ICS, News, Vulnerabilities

Rockwell Automation ISaGRAF5 Runtime (Update A) 

1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: ISaGRAF5 Runtime Vulnerabilities: Use of Hard-coded Cryptographic Key, Unprotected Storage of Credentials, Relative Path Traversal, Uncontrolled Search Path Element, Cleartext Transmission of Sensitive Information\ 2. UPDATE INFORMATION This updated advisory is a follow-up to the…

ThroughTek P2P SDK
ICS, News, Vulnerabilities

ThroughTek P2P SDK 

1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: ThroughTek Equipment: P2P SDK Vulnerability: Cleartext Transmission of Sensitive Information 2. RISK EVALUATION ThroughTek supplies multiple original equipment manufacturers of IP cameras with P2P connections as part of its cloud platform. Successful exploitation of this vulnerability could…

Automation Direct CLICK PLC CPU Modules
ICS, News, Vulnerabilities

Automation Direct CLICK PLC CPU Modules 

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Automation Direct Equipment: CLICK PLC CPU modules Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Cleartext Transmission of Sensitive Information, Unprotected Storage of Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker…

OpenClinic GA
ICS, News, Vulnerabilities

OpenClinic GA (Update B) 

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit/public exploits are available Vendor: OpenClinic GA is a product of open-source collaboration on Source Forge Equipment: OpenClinic GA Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Improper Restriction of Excessive Authentication Attempts, Improper Authentication, Missing…

ZOLL Defibrillator Dashboard
ICS, News, Vulnerabilities

ZOLL Defibrillator Dashboard 

1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: ZOLL Equipment: Defibrillator Dashboard Vulnerabilities: Unrestricted Upload of File with Dangerous Type, Use of Hard-coded Cryptographic Key, Cleartext Storage of Sensitive Information, Cross-site Scripting, Storing Passwords in a Recoverable Format, Improper Privilege Management 2. RISK EVALUATION Successful…