Trending News

Siemens Solid Edge
ICS, News, Vulnerabilities

Siemens Solid Edge 

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Siemens Equipment: Solid Edge Vulnerabilities: Out-of-bounds Write, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow arbitrary code execution on an affected system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions…

Siemens SCALANCE X Products
ICS, News, Vulnerabilities

Siemens SCALANCE X Products (Update A) 

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SCALANCE X Products Vulnerabilities: Missing Authentication for Critical Function, Heap-based Buffer Overflow 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-012-05 Siemens SCALANCE X Products that was…

Siemens Opcenter Execution Core
ICS, News, Vulnerabilities

Siemens Opcenter Execution Core (Update B) 

1. EXECUTIVE SUMMARY CVSS v3 8.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: Opcenter Execution Core ——— Begin Update B Part 1 of 5 ——— Vulnerabilities: Cross-site Scripting, SQL Injection, Improper Access Control, Insufficiently Protected Credentials ——— End Update B Part 1 of 5 ——— 2. UPDATE…

Siemens SCALANCE & SIMATIC
ICS, News, Vulnerabilities

Siemens SCALANCE & SIMATIC (Update D) 

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SCALANCE, SIMATIC Vulnerability: Resource Exhaustion 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-20-105-07 Siemens SCALANCE & SIMATIC (Update C) that was published September 8, 2020, to…

Siemens TIA Portal
ICS, News, Vulnerabilities

Siemens TIA Portal (Update B) 

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Siemens Equipment: TIA Portal Vulnerability: Path Traversal 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-20-014-05 Siemens TIA Portal (Update A) that was published April 14, 2020, to the ICS…

Siemens PROFINET Devices
ICS, News, Vulnerabilities

Siemens PROFINET Devices (Update I) 

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: PROFINET Devices Vulnerability: Uncontrolled Resource Consumption 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-19-283-02 Siemens PROFINET Devices (Update H) that was published September 8, 2020, to…

Innokas Yhtymä Oy Vital Signs Monitor
ICS, News, Vulnerabilities

Innokas Yhtymä Oy Vital Signs Monitor 

1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Innokas Yhtymä Oy Equipment: Vital Signs Monitor VC150 Vulnerabilities: Cross-site Scripting, Improper Neutralization of Special Elements in Output Used by a Downstream Component 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker…